Push button type fibre optic high speed handpiece
Lotus 302PBQ-M4
★ TECHNICAL PARAMETER:
DESCRIPTION
|
Push button type fibre optic high speed handpiece, triple water spray, anti-retraction system, with quick coupling
|
AIR PRESSURE AT THE BACK END OF HP
|
206~231 KPa (2.1~2.35 kgf/cm2)
|
AIR PRESSURE AT THE GAUGE IN THE DENTAL UNIT
|
240-294 KPa (2.45-3.0 kgf/cm2)
|
WATER PRESSURE
|
198Kpa (2 kg)
|
ROTATION SPEED
|
300,000-320,000 rpm
|
HEAD HIGHT
|
13.02 mm
|
HEAD DIAMETRE
|
φ12.5 mm
|
CHUCK TYPE
|
Push button
|
BUR APPLICABLE
|
φ1.59mm~φ1.6mm×21mm~23mm (diameter×length)
|
NOISE
|
≤70dB
|
INTENSITY OF LIGHT
|
25000 lx
|
SOURCE OF LIGHT
|
Haloid bulb
|
VOLT OF BULB
|
3.0~3.2 V
|
SAFETY CLASSIFICATION
|
B type application part
|
LOTUS 302PQ
★ TECHNICAL PARAMETER:
DESCRIPTION
|
Push button type high speed handpiece, triple water spray, anti-retraction system, with quick coupling
|
AIR PRESSURE AT THE BACK END OF HP
|
206~231 KPa (2.1~2.35 kgf/cm2)
|
AIR PRESSURE AT THE GAUGE IN THE DENTAL UNIT
|
240-294 KPa (2.45-3.0 kgf/cm2)
|
WATER PRESSURE
|
198Kpa (2 kg)
|
ROTATION SPEED
|
300,000-320,000 rpm
|
HEAD HIGHT
|
13.02 mm
|
HEAD DIAMETRE
|
φ12.5 mm
|
CHUCK TYPE
|
Push button
|
BUR APPLICABLE
|
φ1.59mm~φ1.6mm×21mm~23mm (diameter×length)
|
NOISE
|
≤70dB
|
Lotus 302PB-M4 302PB-B2
★ TECHNICAL PARAMETER:
DESCRIPTION
|
Push button type fibre optic high speed handpiece, triple water spray, anti-retraction system
|
AIR PRESSURE AT THE BACK END OF HP
|
206~231 KPa (2.1~2.35 kgf/cm2)
|
AIR PRESSURE AT THE GAUGE IN THE DENTAL UNIT
|
240-294 KPa (2.45-3.0 kgf/cm2)
|
WATER PRESSURE
|
198Kpa (2 kg)
|
ROTATION SPEED
|
≥320,000 rpm
|
HEAD HIGHT
|
13.02 mm
|
HEAD DIAMETRE
|
φ12.5 mm
|
CHUCK TYPE
|
Push button
|
BUR APPLICABLE
|
φ1.59mm~φ1.6mm×21mm~23mm (diameter×length)
|
NOISE
|
≤70dB
|
INTENSITY OF LIGHT
|
25000 lx
|
SOURCE OF LIGHT
|
Haloid bulb
|
Lotus 302P-M4 302P-B2
★ TECHNICAL PARAMETER:
DESCRIPTION
|
Triple spray system high speed handpiece, push button type, anti-retraction system
|
AIR PRESSURE AT THE BACK END OF HP
|
206~231 KPa (2.1~2.35 kgf/cm2)
|
AIR PRESSURE AT THE GAUGE IN THE DENTAL UNIT
|
240-294 KPa (2.45-3.0 kgf/cm2)
|
WATER PRESSURE
|
198Kpa (2 kg)
|
ROTATION SPEED
|
300,000-320,000 rpm
|
HEAD HIGHT
|
13.02 mm
|
HEAD DIAMETRE
|
φ12.5 mm
|
CHUCK TYPE
|
Push button
|
BUR APPLICABLE
|
φ1.59mm~φ1.6mm×21mm~23mm (diameter×length)
|
NOISE
|
≤70dB
|
Lotus 401P-M4 401P-B2
★ TECHNICAL PARAMETER:
DESCRIPTION
|
Standard head high-speed handpiece
Push button type
Single spray system
|
AIR PRESSURE
|
180-250 KPa (1.8-2.5 kgf / cm2)
|
WATER PRESSURE
|
198Kpa (2 kg)
|
ROTATION SPEED
|
370,000- 420,000 rpm
|
HEAD HIGHT
|
14.6 mm
|
HEAD DIAMETRE
|
Φ11.2 mm
|
CHUCK TYPE
|
Push button
|
BUR APPLICABLE
|
φ1.59mm~φ1.6mm×21mm~23mm (diameter×length)
|
NOISE
|
≤70dB
|
|